Back to Product Search

CLP Single Fluid Heating System

Sectors

  • Engine

Product Categories

Large capacity coolant heater for stationary land power applications

Hotstart’s CLP is a large capacity coolant heating system designed to maintain optimal temperatures for diesel and gas engines in stationary land power and marine applications. Designed as a user-friendly, pre-packaged system, the CLP includes all necessary components. The CLP's remote automatic function and customer interface connections enable it to be easily integrated into any control system.

To improve equipment startability and availability, the CLP maintains a consistent and uniform temperature by circulating heated coolant throughout the engine block – eliminating hot spots and preventing overheating at engine shutdown. When compared to cold engine starts, maintaining optimal temperature during down time lowers NOx emissions at engine startup. Engine heating also eliminates the need for extended idling, reducing overall maintenance expenses.

In warmer, humid climates, temperature variation can cause condensation to collect in the cylinders, resulting in starting issues and frequent maintenance. By maintaining temperatures above the dew point, the CLP eliminates the risk of condensation forming inside the heads during cool down periods.

Not intended for hazardous locations.

Heating Information

Primary Heating

  • Coolant Mix

Primary Heat Power

  • 11 kW
  • 12 kW
  • 17 kW
  • 18 kW
  • 24 kW
  • 30 kW
  • 33 kW
  • 36 kW

Power Specifications

Power Sources

  • AC, Single-Phase, 60 Hz
  • AC, Single-Phase, 50 Hz
  • AC, Three-Phase, 60 Hz
  • AC, Three-Phase, 50 Hz

Voltages

  • 230
  • 240
  • 380
  • 440
  • 400
  • 480
  • 600
  • 690

Power Connectors

  • Hardwired

Temperature Control

Primary Temperature Control

  • 32–176°F (0–80°C), adjustable

Primary Temperature Control Set Points

  • 122°F (50°C), factory set

Primary High Limit Temperature

  • 195°F (90°C)

Mount Types

  • Plate

Inlets / Outlets

Inlets

  • 1” NPT

Outlets

  • 1” NPT

Ingress Options

Control Box Ingress

  • NEMA 4
  • IP66

Coolant Motor Ingress

  • IP55

Certifications

  • CSA C/US
  • CE-compliant models available

Related Products

Designed to preheat coolant and oil, the DLV eliminates unnecessary idling  and keeps oil at optimal temp.

HOTSTART's DLV Dual Fluid Electrical Engine Heater is designed to preheat coolant and oil to heat the prime movers of locomotives as well as diesel and gas engines of generators, marine vessels and…

read more

The CLV is a complete system designed to preheat coolant,  eliminate idling, save fuel and reduce wear.

HOTSTART's CLV Single Fluid Electrical Engine Heater is designed to preheat coolant to heat the prime movers of locomotives as well as diesel and gas engines of generators, marine vessels and mining…

read more

CSA US certified coolant preheater designed to maintain optimal temp for oil & gas applications.

The OCLP model (CSA US Certified) is a coolant preheater designed to maintain optimal temperatures for diesel and gas engines in stationary land power and marine applications. The OCLP is designed as…

read more

Large capacity oil heater for stationary land power applications

Hotstart’s OLP is a large capacity oil heating system designed to maintain optimal temperatures for diesel and gas engines in stationary land power and marine applications. Designed as a…

read more