Back to Product Search

EE Engine Heater

Sectors

  • Energy
  • Engine

Product Categories

Hazardous location approved systems that are hard wired into the main electrical system.

HOTSTART’s EE heaters are hazardous location approved systems available in both single and three phase configurations that are hard wired into the main electrical system. The EE series features the same pressure die-cast aluminum tank, built-in high limit thermostat and optional flow-through thermostat as our line of CB/CL heaters. The EE series adds an all-metal mounting bracket and heat power up to 5 kW, making it ideal for heavy-duty large engine applications for Class I, Group D (Hazardous Locations).

Mounted externally from the engine block and utilizing convection – the natural rising of heated fluid – thermosiphon heaters require no additional pump and can be installed on a wide range of engines without requiring a specific part to conform to the water jacket. This adaptable and effective heating system makes thermosiphon heaters the ideal option for a wide variety of engine heating applications.

Preheating diesel or gas engines ensures they are ready to start and assume full load quickly with minimal wear to critical components. Industries that rely on their engines or backup power systems to ensure day-to-day operations run smoothly, such as fleet vehicles, excavation, mining, data centers and hospitals depend on the benefits provided by consistent engine heating to maximize their equipment investment and eliminate downtime.

Can be used in hazardous locations.

Heating Information

Primary Heating

  • Coolant Mix

Primary Heat Power

  • 1.5 kW
  • 2 kW
  • 2.5 kW
  • 3 kW
  • 4 kW
  • 5 kW

Power Specifications

Power Sources

  • AC, Three-Phase, 50/60 Hz
  • AC, Single-Phase, 50/60 Hz

Voltages

  • 120
  • 208
  • 240
  • 480

Power Connectors

  • Hardwired

Temperature Control

Primary Temperature Control

  • 100–120 °F (38–49 °C)

Mount Types

  • Bracket

Inlets / Outlets

Inlets

  • 1” NPT

Outlets

  • 1” NPT

Certifications

  • North American Listed Class 1, Group D components

Related Products

Compact heaters that feature a built-in thermostat and multiple heat and voltage options for diesel or gas engines.

Made from pressure die-cast aluminum tanks, HOTSTART’s CB series of heaters are the compact, heavy-duty solution for heating your diesel or gas engine. Featuring a built-in high-limit thermostat,…

read more

Capable of providing a disconnection point and overcurrent protection when paired with hazardous location heating systems

HOTSTART’s explosion proof BB Breaker Box is capable of providing a disconnection point and overcurrent protection when paired with HOTSTART hazardous location heating systems for oil and gas…

read more

CL heaters are heavy-duty thermosiphon heating solution,  providing higher wattage options for increased heat output.

HOTSTART’s CL heaters are the heavy-duty thermosiphon heating solution, providing higher wattage options for increased heat output. The CL series features the same pressure die-cast aluminum tank,…

read more

Hotstart’s largest capacity UL C/US combination heating system designed  for hazardous locations in North America.

The OCLE model (UL C/US listed; Class 1, Div 1, Group D T3 or Class 1 Zone 1 Group IIA T3 depending on configuration) is HOTSTART’s largest capacity combination coolant-oil heating system designed…

read more

Engine block heater used for heating coolant consists of a metal tank  with power cord and thermostat enclosure attached

Made from pressure die-cast aluminum tanks, HOTSTART’s SB series of heaters are the compact, heavy-duty solution for aftermarket applications requiring heat for your diesel or gas engine. Featuring…

read more

Engine block heater used for heating coolant consists of a metal tank  with power cord and thermostat enclosure attached

Made from pressure die-cast aluminum tanks, HOTSTART’s SL series of heaters are the compact, heavy-duty solution for aftermarket applications requiring heat for your diesel or gas engine. The SL…

read more

Engine block heater used for heating coolant consists of a metal tank  with thermostat enclosure attached but no power cord

HOTSTART’s WL heaters are the three phase option for dependable heating of original equipment manufacturers' engines. The WL series features the same pressure die-cast aluminum tank, built-in high…

read more

Hotstart's lube oil heaters thread into the engine’s oil pan to  keep the oil warm.

Hotstart lube oil heaters thread into the engine’s oil pan to keep the oil warm. When cold, oil becomes very viscous and may not protect engine components. Upon start-up, warm oil is supplied to the…

read more

Hotstart’s OLE is the largest capacity UL C/US oil heating system designed for hazardous locations in North America.

The OLE model (UL C/US listed; Class 1, Div 1, Group D T3 or Class 1 Zone 1 Group IIA T3 depending on configuration) is HOTSTART’s largest capacity oil heating system designed for use in North…

read more

UL C/US Systems designed for hazardous locations and designed to handle the largest engine heating applications.

The CLE model (UL C/US listed; Class 1, Div 1, Group D T3 or Class 1 Zone 1 Group IIA T3 depending on configuration) is HOTSTART’s large capacity coolant heating system designed for use in North…

read more

Hotstart’s largest capacity combination, IECEx oil & gas heating system designed for hazardous locations.

The OCLA model (IECEx certified) is HOTSTART’s largest capacity combination coolant-oil heating system designed for use in hazardous location applications. Its combination of heating power options…

read more

Hotstart’s OLA is the largest capacity IECEx oil heating system designed for hazardous locations.

The OLA model (IECEx certified) is HOTSTART’s largest capacity oil heating system designed for use in hazardous location applications. Its combination of heating power options (up to 24 kW) and pump…

read more

IECEx systems designed for hazardous locations and designed to handle the largest engine heating applications.

The CLA model (IECEx certified) is HOTSTART’s large capacity coolant heating system designed for use in hazardous location applications. Its combination of heating power options (up to 66 kW) and…

read more

A compact UL C/US heating system for use in North America to maintain  optimal engine temperatures-front view shown.

HOTSTART’s CSE (UL C/US listed; Class 1, Div. 2, Group D, T3 or Class 1, Zone 2, Group IIA T3 depending on configuration) is a compact coolant heating system for use in North American hazardous…

read more

A compact UL C/US combination oil and coolant heating system for North American hazardous locations designed to maintain engine temp-front view.

HOTSTART's OCSE (UL C/US listed; Class 1, Div. 2, Group D, T3 or Class 1, Zone 2, Group IIA T3 depending on configuration) is a compact combination oil and coolant heating system for use in North…

read more